Type:CX-LCM-1607A lab conductivity meter

Illustrate:It can be widely used for continuous monitoring of conductivity values of the solutions in thermal power plants, chemical fertilizer, metallurgy, environmental protection, pharmaceutical industry, biochemical industry, foodstuff and running water.

CX-LCM-1607A Lab Conductivity Meter

Main Features
1.Double-row nixie tube: To show the conductivity and temperature values respectively
2.Computer-based: It adopts the high-performance CPU chip, high-precision AD conversion technology and SMT technology to complete the multi-parameter measurement, temperature compensation and automatic range switching, with high precision and good repeatability.
3.Reliability: Single board structure, touch button, no switch knob or potentiometer
4.Automatic conversion of measuring frequency: To avoid the electrode polarization and improve the Measurement accuracy
5.25°C Conversion: Temperature compensation automatic measurement/manual input, with the waterproof and anti-corrosion design
6.Network function: RS232 bi-directional communication; it can be equipped with a printer or TLab8.0communications and data processing software
7.Measurable high-purity water: Equipped with titanium alloy electrode with the constant of 0.01 cm-1 and an airtight measuring cell; automatic prompting for measuring terminal.
 
Main parameters

Display Double-row Nixie tube displays the conductivity
and temperature values respectively
Measuring range  (1-30000) μ s/cm, 0-99.9 °C
Electrode constant 0.01-30 μ s/cm (Electrode: K=0.01) ,0.1~300 μ s/cm
(Electrode: K=0. 1)
1.0~3000 μ s/cm (Electrode: K=1.0),10~30000 μ s/cm
(Electrode: K=10.0)
Resolution 0.001μ s/cm, 0.1°C
Electrode constant 0.001~15.0 cm-1 set by the software
Temperature compensated range automatic: 0-99.9 °C, manual: 0-99.9 °C
Temperature coefficient 0~10%/°C (with 25°C as the reference temperature)
Accuracy ±l0%FS, ±0 3°C
Communication interface RS232 bi-directional communication interface
Power supply AC220V ± 22V, 50Hz ± 1Hz, external power supply
Working conditions ambient temperature: 0-60°C; relative humidity: ≤90
Power-down memory: > 5 years
Note:Standard configuration: One secondary instrument; one power supply; one bright or platinum black conductivity electrode with constant l.0; one temperature electrode; a set of electrode support

Last:CX-LCM-1601 lab conductivity me.. Next:CX-LCM-1607 laboratory conducti..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關閉
主站蜘蛛池模板: 万宁市| 桐梓县| 沙洋县| 商洛市| 航空| 兴山县| 抚顺县| 浑源县| 连云港市| 灵川县| 汕头市| 蒙阴县| 惠东县| 竹溪县| 娱乐| 汤阴县| 远安县| 庐江县| 博客| 江口县| 武夷山市| 甘泉县| 明溪县| 芒康县| 永昌县| 达拉特旗| 兴安县| 武城县| 吉木萨尔县| 淮南市| 冀州市| 巴彦县| 武胜县| 土默特右旗| 汉阴县| 黎平县| 贞丰县| 武宣县| 云阳县| 金沙县| 仙游县|